8010405 - | HERU 200 T EC AR 2300W | 8010407 - | HERU 200 T EC AL 2300W | 8010406 - | HERU 200 T EC CR |
8010408 - | HERU 200 T EC CL |
NOTE! The warranty of The HERU is only valid if accessories/equipment (e.g. filters) from H. Östberg AB are used.
HERU 200 T EC AR 2300W 8010405 |
HERU 200 T EC AL 2300W 8010407 |
HERU 200 T EC CR 8010406 |
HERU 200 T EC CL 8010408 |
|||||
---|---|---|---|---|---|---|---|---|
Parameter | Value | Unit | Value | Unit | Value | Unit | Value | Unit |
Voltage | 230 | V | 230 | V | 230 | V | 230 | V |
Phase | 1 | ~ | 1 | ~ | 1 | ~ | 1 | ~ |
Frequency | 50 | Hz | 50 | Hz | 50 | Hz | 50 | Hz |
Power | 2650 | W | 2650 | W | 348 | W | 348 | W |
Power, fans | 321 | W | 321 | W | 321 | W | 321 | W |
Power, heater | 2300 | W | 2300 | W | 0 | W | 0 | W |
Current | 12.7 | A | 12.7 | A | 2.66 | A | 2.66 | A |
Current, fans | 2.56 | A | 2.56 | A | 2.56 | A | 2.56 | A |
Current, heater | 10.00 | A | 10.00 | A | 0 | A | 0 | A |
Speed | 2780 | r.p.m. | 2780 | r.p.m. | 2780 | r.p.m. | 2780 | r.p.m. |
Sound pressure level at 3 m | 43 | dB(A) | 43 | dB(A) | 43 | dB(A) | 43 | dB(A) |
Weight | 132.0 | kg | 132.0 | kg | 130.0 | kg | 130.0 | kg |
Enclosure class | 41 | IP | 41 | IP | 41 | IP | 41 | IP |
Duct connection | 250 | mm | 250 | mm | 250 | mm | 250 | mm |
Max. flow @ 0Pa | 230 | l/s | 230 | l/s | 230 | l/s | 230 | l/s |
Max. pressure | 914 | Pa | 914 | Pa | 914 | Pa | 914 | Pa |
Voltage range | 220-240 | V | 220-240 | V | 220-240 | V | 220-240 | V |
Parameter | Value | Unit |
---|---|---|
(a) Manufacturer | Östberg | - |
(b) Model code | HERU 200 T EC | - |
(c) SEC value | -41.72 | kWh/m2 |
SEC class | A | - |
(d) Declared type | RVU / BVU | - |
(e) Type of drive | Variable speed drive | - |
(f) Type of heat recovery | Regenerative | - |
(g) Thermal efficiency | 86% | % |
(h) Max. flow rate (@100Pa) | 744 | m3/h |
(i) Power at max. flow rate | 317 | W |
(j) Sound power level | 45 | dB LwA |
(k) Reference flow rate | 0.153 | m3/s |
(l) Reference pressure difference | 50 | Pa |
(m) SPI | 0.30 | W/(m3/h) |
(n) Type of control/ctrl factor | Local demand control/0.65 | - |
(o) External (and internal) leakage rate | 1.75 (2.51) | % |
(p) Mixing rate | N/A | - |
(q) Visual filter warning | In remote control | - |
(r) Instruction supply/exhaust grilles | N/A | - |
(s) Disassembly instructions | www.ostberg.com | - |
(t) Airflow sensitivity | N/A | - |
(u) Air tightness | N/A | m/s |
(v) AEC | 202 | kWh |
(w) AHS average | 4637 | kWh |
AHS warmer | 2097 | kWh |
AHS colder | 9071 | kWh |