| 8000010 - | SAU 125 A1 man tc |



Generating diagrams...
Generating diagrams...
|
SAU 125 A1 man tc 8000010 |
||
|---|---|---|
| Parameter | Value | Unit |
| Voltage | 230 | V |
| Phase | 1 | ~ |
| Frequency | 50 | Hz |
| Power | 1041 | W |
| Power, fans | 41 | W |
| Power, heater | 1000 | W |
| Current | 4.5 | A |
| Speed | 1100 | r.p.m. |
| Sound pressure level at 3 m | 38 | dB(A) |
| Weight | 19 | kg |
| Enclosure class | 44 | IP |
| Insulation class, motor | F | |
| Capacitor | 3 | µF |
| Duct connection | 125 | mm |
| Max. flow @ 0Pa | 49 | l/s |
| Max. pressure | 261 | Pa |
| Voltage range | 220-240 | V |
| Parameter | Value | Unit |
|---|---|---|
| (a) Manufacturer | Östberg | - |
| (b) Model code | SAU 125 A1 | - |
| (c) SEC value | -2.6 | kWh/m2 |
| SEC class | F | - |
| (d) Declared type | RVU / UVU | - |
| (e) Type of drive | Multi-speed drive (accessory) | - |
| (f) Type of heat recovery | N/A | - |
| (g) Thermal efficiency | N/A | % |
| (h) Max. flow rate (@100Pa) | 135 | m3/h |
| (i) Power at max. flow rate | 53 | W |
| (j) Sound power level | 45 | dB LwA |
| (k) Reference flow rate | 0.026 | m3/s |
| (l) Reference pressure difference | 189 | Pa |
| (m) SPI | 0.46 | W/(m3/h) |
| (n) Type of control/ctrl factor | Manual control | - |
| (o) External (and internal) leakage rate | 0.59 | % |
| (p) Mixing rate | N/A | - |
| (q) Visual filter warning | N/A | - |
| (r) Instruction supply/exhaust grilles | See manual | - |
| (s) Disassembly instructions | www.ostberg.com | - |
| (t) Airflow sensitivity | N/A | - |
| (u) Air tightness | N/A | m/s |
| (v) AEC | 625 | kWh |
| (w) AHS average | 2005 | kWh |
| AHS warmer | 907 | kWh |
| AHS colder | 3922 | kWh |