| 7001239 - | CK 125 C1 EC-y2 | 
                                
                                
                                
                                
                                
                         
 Generating diagrams...
                            
 Generating diagrams...
                            | 
                                                            CK 125 C1 EC-y2 7001239  | 
                                                                                                    ||
|---|---|---|
| Parameter | Value | Unit | 
| Voltage | 230 | V | 
| Phase | 1 | ~ | 
| Frequency | 50/60 | Hz | 
| Power | 99 | W | 
| Current | 0.83 | A | 
| Speed | 3600 | r.p.m. | 
| Max. temperature of transported air | 60 | °C | 
| Sound pressure level at 3 m | 46 | dB(A) | 
| Weight | 2.5 | kg | 
| Enclosure class | 44 | IP | 
| Insulation class, motor | F | |
| Duct connection | 125 | mm | 
| Max. flow @ 0Pa | 158 | l/s | 
| Max. pressure | 582 | Pa | 
| Voltage range | 200-277 | V | 
| Parameter | Value | Unit | 
|---|---|---|
| (a) Manufacturer | Östberg | - | 
| (b) Model code | CK 125 C1 EC | - | 
| (c) Declared type | NRVU / UVU | - | 
| (d) Type of drive | Variable speed drive | - | 
| (e) Type of HRS | N/A | - | 
| (f) Thermal efficiency | N/A | % | 
| (g) Nominal flow rate | 0.050 | m3/s | 
| (h) Effective power input | 0.075 | kW | 
| (i) SFP int | N/A | W/(m3/s) | 
| (j) Face velocity | 4 | m/s | 
| (k) Nominal external pressure | 467 | Pa | 
| (l) Internal pressure drop | N/A | Pa | 
| (n) Static efficiency | 45.0 | % | 
| (o) External (and internal) leakage rate | 0.67 (N/A) | % | 
| (p) Filter classification | N/A | - | 
| (q) Visual filter warning | N/A | - | 
| (r) Sound power level | 53 | dB LwA | 
| (s) Disassembly instructions | fsp.ostberg.com | - |