8000011 - | SAU 125 A1 man tp with pulser |
SAU 125 A1 man tp with pulser 8000011 |
||
---|---|---|
Parameter | Value | Unit |
Voltage | 230 | V |
Phase | 1 | ~ |
Frequency | 50 | Hz |
Power | 1041 | W |
Power, fans | 41 | W |
Power, heater | 1000 | W |
Current | 4.5 | A |
Speed | 1100 | r.p.m. |
Sound pressure level at 3 m | 38 | dB(A) |
Weight | 19.6 | kg |
Enclosure class | 44 | IP |
Insulation class, motor | F | |
Capacitor | 3 | µF |
Duct connection | 125 | mm |
Max. flow @ 0Pa | 49 | l/s |
Max. pressure | 261 | Pa |
Voltage range | 220-240 | V |
Parameter | Value | Unit |
---|---|---|
(a) Manufacturer | Östberg | - |
(b) Model code | SAU 125 A1 Pulser | - |
(c) SEC value | -2.6 | kWh/m2 |
SEC class | F | - |
(d) Declared type | RVU / UVU | - |
(e) Type of drive | Multi-speed drive (accessory) | - |
(f) Type of heat recovery | N/A | - |
(g) Thermal efficiency | N/A | % |
(h) Max. flow rate (@100Pa) | 135 | m3/h |
(i) Power at max. flow rate | 53 | W |
(j) Sound power level | 45 | dB LwA |
(k) Reference flow rate | 0.026 | m3/s |
(l) Reference pressure difference | 189 | Pa |
(m) SPI | 0.46 | W/(m3/h) |
(n) Type of control/ctrl factor | Manual control | - |
(o) External (and internal) leakage rate | 0.59 | % |
(p) Mixing rate | N/A | - |
(q) Visual filter warning | On label | - |
(r) Instruction supply/exhaust grilles | See manual | - |
(s) Disassembly instructions | www.ostberg.com | - |
(t) Airflow sensitivity | N/A | - |
(u) Air tightness | N/A | m/s |
(v) AEC | 625 | kWh |
(w) AHS average | 2005 | kWh |
AHS warmer | 907 | kWh |
AHS colder | 3922 | kWh |