| 8010370 - | HERU 160 T EC AR 1700W | 8010371 - | HERU 160 T EC AL 1700W | 8010372 - | HERU 160 T EC ARC 1700W |
| 8010373 - | HERU 160 T EC ALC 1700W | 8010381 - | HERU 160 T EC BL 850W | 8010380 - | HERU 160 T EC BR 850W |
| 8010391 - | HERU 160 T EC CL | 8010390 - | HERU 160 T EC CR |



│ Ten produkt wygaśnie! │
HERU®160 T EC
Generating diagrams...
Generating diagrams...
|
HERU 160 T EC AR 1700W 8010370 |
HERU 160 T EC AL 1700W 8010371 |
HERU 160 T EC ARC 1700W 8010372 |
HERU 160 T EC ALC 1700W 8010373 |
HERU 160 T EC BL 850W 8010381 |
HERU 160 T EC BR 850W 8010380 |
HERU 160 T EC CL 8010391 |
HERU 160 T EC CR 8010390 |
|||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Parameter | Value | Unit | Value | Unit | Value | Unit | Value | Unit | Value | Unit | Value | Unit | Value | Unit | Value | Unit |
| Napięcie | 230 | V | 230 | V | 230 | V | 230 | V | 230 | V | 230 | V | 230 | V | 230 | V |
| Faza | 1 | ~ | 1 | ~ | 1 | ~ | 1 | ~ | 1 | ~ | 1 | ~ | 1 | ~ | 1 | ~ |
| Częstotliwość | 50 | Hz | 50 | Hz | 50 | Hz | 50 | Hz | 50 | Hz | 50 | Hz | 50 | Hz | 50 | Hz |
| Moc | 2050 | W | 2050 | W | 2050 | W | 2050 | W | 1200 | W | 1200 | W | 348 | W | 348 | W |
| Moc, wentylatory | 321 | W | 321 | W | 321 | W | 321 | W | 321 | W | 321 | W | 321 | W | 321 | W |
| Moc nagrzewnica | 1700 | W | 1700 | W | 1700 | W | 1700 | W | 850 | W | 850 | W | 0 | W | 0 | W |
| Prąd | 10 | A | 10 | A | 10 | A | 10 | A | 6.3 | A | 6.3 | A | 2.63 | A | 2.63 | A |
| Prąd, wentylator | 2.53 | A | 2.53 | A | 2.53 | A | 2.53 | A | 2.53 | A | 2.53 | A | 2.53 | A | 2.53 | A |
| Prąd nagrzewnica | 7.39 | A | 7.39 | A | 7.39 | A | 7.39 | A | 3.7 | A | 3.7 | A | 0 | A | 0 | A |
| Prędkość | 3070 | r.p.m. | 3070 | r.p.m. | 3070 | r.p.m. | 3070 | r.p.m. | 3070 | r.p.m. | 3070 | r.p.m. | 3070 | r.p.m. | 3070 | r.p.m. |
| Poziom ciśnienia akustycznego w odl. 3 m | 45 | dB(A) | 45 | dB(A) | 45 | dB(A) | 45 | dB(A) | 45 | dB(A) | 45 | dB(A) | 45 | dB(A) | 45 | dB(A) |
| Waga | 91.0 | kg | 91.0 | kg | 91.0 | kg | 91.0 | kg | 91 | kg | 91 | kg | 90.0 | kg | 90.0 | kg |
| Klasa ochrony, silnik | 41 | IP | 41 | IP | 41 | IP | 41 | IP | 41 | IP | 41 | IP | 41 | IP | 41 | IP |
| Przyłącza kanałów | 160 | mm | 160 | mm | 160 | mm | 160 | mm | 160 | mm | 160 | mm | 160 | mm | 160 | mm |
| Maks. Wydatek @ 0Pa | 176 | l/s | 176 | l/s | 176 | l/s | 176 | l/s | 176 | l/s | 176 | l/s | 176 | l/s | 176 | l/s |
| Maks. Ciśnienie | 874 | Pa | 874 | Pa | 874 | Pa | 874 | Pa | 874 | Pa | 874 | Pa | 874 | Pa | 874 | Pa |
| Zakres napięcia | 220-240 | V | 220-240 | V | 220-240 | V | 220-240 | V | 220-240 | V | 220-240 | V | 220-240 | V | 220-240 | V |
| Parameter | Value | Unit |
|---|---|---|
| (a) Nazwa dostawcy lub znak towarowy | Östberg | - |
| (b) Identyfikator modelu | HERU 160 T EC | - |
| (c) SEC value | -38.83 | kWh/m2 |
| SEC class | A | - |
| (d) Typologia | RVU / BVU | - |
| (e) Rodzaj napędu | Variable speed drive | - |
| (f) Typ układu odzysku ciepła | Regenerative | - |
| (g) Sprawność cieplna odzysku ciepła | 84 | % |
| (h) Maksymalna wartość natężenia przepływu | 575 | m3/h |
| (i) Pobór mocy napędu wentylatora | 314 | W |
| (j) Poziom mocy akustycznej | 48 | dB LwA |
| (k) Natężenie przepływu strumienia odniesienia | 0.132 | m3/s |
| (l) Wartość odniesienia różnicy ciśnienia | 50 | Pa |
| (m) Jednostkowy pobór mocy | 0.48 | W/(m3/h) |
| (n) Typ sterowania/Czynnik rodzaju sterowania | Local demand control/0.65 | - |
| (o) Stopnie zewnętrznych (i wewnętrzny) przecieków powietrza | 2.26 (2.69) | % |
| (p) Szybkość mieszania | N/A | - |
| (q) Umiejscowienie mechanizmu wizualnego ostrzeżenia o konieczności wymiany filtra | In remote control | - |
| (r) Instrukcje montażu | N/A | - |
| (s) Instrukcje montażu wstępnego/demontażu - URL | www.ostberg.com | - |
| (t) Czułość przepływu powietrza | N/A | - |
| (u) Szczelność powietrzna | N/A | m/s |
| (v) Roczne zużycie energii elektrycznej | 302 | kWh |
| (w) Roczne oszczędności w ogrzewaniu w klimacie umiarkowanym | 4599 | kWh |
| Roczne oszczędności w ogrzewaniu w klimacie ciepłym | 2080 | kWh |
| Roczne oszczędności w ogrzewaniu w klimacie chłodnym | 8997 | kWh |