8010030 - | TERU insulated |
TERU consists of supply and exhaust radial fans, rotary heat exchangers and filters in class G4. Only valid for the Scandinavian market.
The unit is manufactured from galvanised steel sheet and can withstand a wet environment.
The unit is placed near the outer wall.
The ventilation principle is that TERU provides the foundation with warm or cool filtered, clean, fresh air, and is headed in the back of the foundation through a duct system.
The exhaust air delivers its heat resp cooling in the rotor and is than taken out through a diffuser on the unit.
TERU insulated 8010030 |
||
---|---|---|
Parameter | Value | Unit |
Voltage | 230 | V |
Phase | 1 | ~ |
Frequency | 50 | Hz |
Power | 165 | W |
Current | 0.73 | A |
Speed | 1800 | r.p.m. |
Max. temperature of transported air | 60 | °C |
Sound pressure level at 3 m | 40 | dB(A) |
Weight | 25.3 | kg |
Enclosure class | 44 | IP |
Insulation class, motor | F | |
Capacitor | 2 | µF |
Duct connection | 160 mm | mm |
Voltage range | 220-240 | V |